DC High Voltage Generators
300W to 2kW SR Series
From 300V to over 200kV output voltage
SR60kV-1.2kW
0 to 60kV, 0 to 20mA
Non-contractual photo
Main information Description
Compact & industrial design The numerous advantages of compactness,
Double resonance technology (ZVC) robustness, reliability, and saving offered by
Low stored energy the double resonance technology are already
High reliability & efficiency available on these models which constitute
Voltage & Current outputs continuously the low end range.
adjustable from 0 to 100% Four series of power are offered:
Voltage setting limitation (locally) 300W, 600W, 1.2kW and 2kW.
Voltage & Current Setting & monitoring from
These products are all based on 3U and 5U
front panel or remote interface height 19’’ rack presentation.
Customized Voltage & Current* with no extra
Using a modular design, our products
cost integrate the latest technology components.
High precision regulation
Total protection against arc, overload, short Above 20KV, HV blocks are in resin.
circuit & over temperature
Automatic Regulation crossover
Over current limitation
Remote, inhibit & interlock functions
4 ½ digit display with polarity display
Safety switch key
Air cooling
2 years warranty
* You can choose your own full scales (Vmax and Imax) even if these
values are not available in standard.
For example, you can get a 3750 V generator based on 1.5 kW model.
In this case, you will get an output voltage adjustable from 0 to 3750 V
and an output current from 0 to 0.4 A.
TECHNIX
8, rue Eugène Dupuis
94 000 CRETEIL – France
Tel : +33(0)1 56 71 28 60
www.technix-hv.com
190417SR300W-2KW
Page 2/3
Electrical specifications
Output Voltage and Output Current Stored energy: 1 J/ kW
Both Voltage Output and Current Output are continuously
adjustable from 0 to 100% (full scale) Stability (after one hour warm-up)
Local mode: by using 10 turn potentiometers resolution 0.05% 0.01% / hour, operating at constant load and constant
Remote mode: by external 0 to 10V ambient temperature
Voltage regulation* Temperature Coefficient: 100 ppm/°C
Load Regulation: ± 0.05% of full voltage (for 0 – 100% load)
Operating Temperature: from 0 to 50°C
± 0.01% available on request
Line Regulation: ± 0.05% of full load (for Mains Voltage ± 10%) Efficiency: > 90% at full load
± 0.01% available on request Air Cooling by air :
Dust filter fans on front panel
Current regulation* Easily removable filters for cleaning
Load Regulation: ± 0.05% of full current (for 0 – 100% load)
Line Regulation: ± 0.05% of full load (for Mains Voltage ± 10%) Mains Voltage
170V to 255VAC 47-63Hz Single Phase + Earth
Ripple + Noise
0.1% RMS of full voltage Power Factor Correction Input: ≥ 0.98
Settling time Inrush current: limited to full power operating current
80ms typical for output voltage ≤ 80kV**, up to 10ms
available on request* Calibration: with probes periodically approved by
Authorized Measurement Laboratories
Protections
Short circuit CE Certification
HV arc to ground (Stop time of 100ms)
Shutdown on Over temperature
Open interlock
* For fixed polarity
** 300 ms typical for output voltage ≥81kV
Options
Other voltage and current values available with no Adaptation to Customer’s remote interface
extra cost Emergency stop switch
Reversibility Safety signs and devices alerting to hazard
Floating outputs (unipolar or bipolar) Industrial dust filters
Non instrumented front panel Multichannel control unit
Power regulation Zero floating
Other settings for Arc protection Adjustable rise time
Arc management Tropicalization
RS232, Ethernet and Profibus interfaces Transportable “all terrain” container
Optical fibre transmission kit with RS232 or Ethernet Specific AC or DC mains power inputs
LABVIEW run time for RS232 or Ethernet OEM Design on request
Relay interface 24V DC Remote front panel
Isolated Remote interface Any special request can be considered
Possible restrictions when multiple options are selected (please contact our sales department for more details)
TECHNIX
8, rue Eugène Dupuis
94 000 CRETEIL – France
Tel : +33(0)1 56 71 28 60
www.technix-hv.com
190417SR300W-2KW
Page 3/3
Physical description
Non-contractual photo
19" Rack 3U - 480 mm 3U - 600 mm 5U - 600 mm
H 133 x W 483 x D 480 mm H 133 x W 483 x D 600 mm H 222 x W 483 x D 600 mm
Dimensions
SR 300W Series SR 600W Series SR 1.2KW Series SR 2KW Series
Voltage Current Model Current Model Current Model Current Model
700 V 429 mA SR700V-300W 857 mA SR700V-600W 1.71 A SR700V-1.2KW 2.86 A SR700V-2KW
1 kV 300 mA
2.5 kV 120 mA SR1KV-300W 600 mA SR1KV-600W 1.2 A SR1KV-1.2KW 2A SR1KV-2KW
5 kV 60 mA
10 kV 30 mA SR2.5KV-300W 240 mA SR2.5KV-600W 480 mA SR2.5KV-1.2KW 800 mA SR2.5KV-2KW
15 kV 20 mA
20 kV 15 mA SR5KV-300W 120 mA SR5KV-600W 240 mA SR5KV-1.2KW 400 mA SR5KV-2KW
30 kV 10 mA
40 kV 7.5 mA SR10KV-300W 60 mA SR10KV-600W 120 mA SR10KV-1.2KW 200 mA SR10KV-2KW
50 kV
60 kV 6 mA SR15KV-300W 40 mA SR15KV-600W 80 mA SR15KV-1.2KW
80 kV 5 mA
100 kV 3.75 mA SR20KV-300W 30 mA SR20KV-600W 60 mA SR20KV-1.2KW
120 kV 3 mA
150 kV 2.5 mA SR30KV-300W 20 mA SR30KV-600W 40 mA SR30KV-1.2KW
200 kV 2 mA
> 200 kV 1.5 mA SR40KV-300W 15 mA SR40KV-600W 30 mA SR40KV1.2KW
SR50KV-300W 12 mA SR50KV-600W 24 mA SR50KV-1.2KW
SR60KV-300W 10 mA SR60KV-600W 20 mA SR60KV-1.2KW CONTACT US
SR80KV-300W 7.5 mA SR80KV-600W 15 mA SR80KV-1.2KW
SR100KV-300W 6 mA SR100KV-600W 12 mA SR100KV-1.2KW
SR120KV-300W 5 mA SR120KV-600W 10 mA SR120KV-1.2KW
SR150KV-300W 4 mA SR150KV-600W 8 mA SR150KV-1.2KW
SR200KV-300W 3 mA SR200KV-600W 6 mA SR200KV-1.2KW
CONTACT US
Polarity can be positive, negative, reversible (option) or floating (option)
Floating or reversibility options can modify the size of the unit
Example of reference : SR 15KV- 300W
Mode : SR model (generator)
Voltage : Adjustable from 0 to 15 kV HV connectors and cables available
Power : 300 W
All our generators are delivered with :
HV output:
HV connector and 3 meters HV cable
Mains input:
2 meters CE22 cable
TECHNIX
8, rue Eugène Dupuis
94 000 CRETEIL – France
Tel : +33(0)1 56 71 28 60
www.technix-hv.com
190417SR300W-2KW